Wyoming Whiskey Structural Evaluation
Wyoming Whiskey was faced with the challenge of deciding whether to add to their current structure by adding another story, or should they look to adding to their facilities by another method. To ascertain if the current structure was sound to add to vertically, James Gores and Associates provided structural analysis.
In reviewing the structure, we ascertained that it was constructed on the same location as a previous structure which had burned. Indeed, some of the burned structure was visible inside of the walls of the current structure. Using borescope cameras, we were able to evaluate both visible portions and those portions that are hidden by walls. That evaluation is being considered to provide the client with a sound, scientific analysis on which to base their decision.
Project Documents
Plan Holders of Record